Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.509
Filtrar
1.
Neuroimaging Clin N Am ; 34(2): 191-202, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38604704

RESUMO

Ultrasound evaluation of the brain is performed through acoustic windows. Transcranial Doppler has long been used to monitor patients with subarachnoid hemorrhage for cerebral vasospasm. Transcranial color-coded sonography permits parenchymal B-mode imaging and duplex evaluation. Transcranial ultrasound may also be used to assess the risk of delayed cerebral ischemia, screen patients for the presence of elevated intracranial pressure, confirm the diagnosis of brain death, measure midline shift, and detect ventriculomegaly. Transcranial ultrasound should be integrated with other point-of-care ultrasound techniques as an essential skill for the neurointensivist.


Assuntos
Isquemia Encefálica , Hemorragia Subaracnóidea , Vasoespasmo Intracraniano , Humanos , Hemorragia Subaracnóidea/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Vasoespasmo Intracraniano/diagnóstico por imagem , Encéfalo
2.
Emerg Med Pract ; 26(Suppl 4): 1-28, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38652756

RESUMO

Acute stroke is one of the most common neurologic emergencies encountered by emergency clinicians. While point of care ultrasound has been a core part of emergency clinicians' training and practice for many years, the use of specialized ultrasound modalities in the care of acute ischemic stroke has not been as widely adopted. This review discusses the use of ultrasound in acute stroke, with a focus on applications of interest to emergency clinicians. Transcranial Doppler, carotid Doppler, microembolic signal detection, transthoracic echocardiography, evaluation for collateral circulation and optic nerve sheath diameter measurement are discussed in a case-based format, with a focus on practical applications for emergency clinicians.


Assuntos
Serviço Hospitalar de Emergência , Acidente Vascular Cerebral , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Ultrassonografia/métodos , Ultrassonografia Doppler Transcraniana/métodos , Sistemas Automatizados de Assistência Junto ao Leito
3.
Med Intensiva (Engl Ed) ; 48(3): 165-173, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38431382

RESUMO

Transcranial ultrasonography is a non-invasive, bedside technique that has become a widely implemented tool in the evaluation and management of neurocritically ill patients. It constitutes a technique in continuous growth whose fundamentals (and limitations) must be known by the intensivist. This review provides a practical approach for the intensivist, including the different sonographic windows and planes of insonation and its role in different conditions of the neurocritical patients and in critical care patients of other etiologies.


Assuntos
Ultrassonografia Doppler em Cores , Ultrassonografia Doppler Transcraniana , Humanos , Ultrassonografia Doppler Transcraniana/métodos , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia , Cuidados Críticos
4.
Pediatrics ; 153(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38444343

RESUMO

OBJECTIVE: To assess nationally endorsed claims-based quality measures in pediatric sickle cell anemia (SCA). METHODS: Using data from the Sickle Cell Data Collection programs in California and Georgia from 2010 to 2019, we evaluated 2 quality measures in individuals with hemoglobin S/S or S/ß-zero thalassemia: (1) the proportion of patients aged 3 months to 5 years who were dispensed antibiotic prophylaxis for at least 300 days within each measurement year and (2) the proportion of patients aged 2 to 15 years who received at least 1 transcranial Doppler ultrasound (TCD) within each measurement year. We then evaluated differences by year and tested whether performance on quality measures differed according to demographic and clinical factors. RESULTS: Only 22.2% of those in California and 15.5% in Georgia met or exceeded the quality measure for antibiotic prophylaxis, with increased odds associated with rural residence in Georgia (odds ratio 1.61; 95% confidence interval 1.21-2.14) compared with urban residence and a trend toward increased odds associated with a pediatric hematologist prescriber (odds ratio 1.28; 95% confidence interval 0.97, 1.69) compared with a general pediatrician. Approximately one-half of the sample received an annual assessment of stroke risk using TCD (47.4% in California and 52.7% in Georgia), with increased odds each additional year in both states and among younger children. CONCLUSIONS: The rates of receipt of recommended antibiotic prophylaxis and annual TCD were low in this sample of children with SCA. These evidence-based quality measures can be tracked over time to help identify policies and practices that maximize survival in SCA.


Assuntos
Anemia Falciforme , Acidente Vascular Cerebral , Criança , Humanos , Indicadores de Qualidade em Assistência à Saúde , Acidente Vascular Cerebral/complicações , Anemia Falciforme/epidemiologia , Anemia Falciforme/complicações , Georgia/epidemiologia , Ultrassonografia Doppler Transcraniana
6.
Med. intensiva (Madr., Ed. impr.) ; 48(3): 165-173, Mar. 2024. graf, ilus
Artigo em Espanhol | IBECS | ID: ibc-231022

RESUMO

La ultrasonografía transcraneal es una técnica no invasiva y disponible a pie de cama que se ha convertido en una herramienta accesible y consolidada en la evaluación y el manejo clínico de los pacientes neurocríticos. Se trata de una técnica en continuo crecimiento cuyos fundamentos (y sus limitaciones) deben ser conocidos por el intensivista. Esta revisión aporta un enfoque práctico para el intensivista, incluyendo las diferentes ventanas y planos de insonación y su papel en la patología específica propia de los pacientes neurocríticos y en los pacientes críticos de otras etiologías. (AU)


Transcranial ultrasonography is a non-invasive, bedside technique that has become a widely implemented tool in the evaluation and management of neurocritically ill patients. It constitutes a technique in continuous growth whose fundamentals (and limitations) must be known by the intensivist. This review provides a practical approach for the intensivist, including the different sonographic windows and planes of insonation and its role in different conditions of the neurocritical patients and in critical care patients of other etiologies. (AU)


Assuntos
Humanos , Ultrassonografia Doppler Transcraniana/história , Ultrassonografia Doppler Transcraniana/tendências , Unidades de Terapia Intensiva , Estado Terminal , Ultrassonografia , Ultrassonografia Doppler Dupla , Monitorização Neurofisiológica
7.
Artigo em Russo | MEDLINE | ID: mdl-38465805

RESUMO

Functional transcranial dopplerography (FTCD) is a non-invasive ultrasound examination that allows recording the dynamics of cerebral blood flow parameters under conditions of factors stimulated the activity of the structures of the central nervous system. Judgments about the sensitivity and specificity of FTCD are based on the close connection between changes in the activity of the nervous (somatic) system and the response of regional cerebral blood flow (CBF). The technique is a portable and accessible diagnostic method used in assessing the possibility of expanding functional activity during the recovery period after a stroke. An increase in mental activity in response to the presentation of a cognitive task, accompanied by an increase in glucose and oxygen consumption and naturally requiring an increase in cerebral perfusion parameters, can also be assessed by changes in regional blood flow parameters while maintaining the reactive mechanisms of autoregulation. A search of literature sources was carried out in the electronic databases PubMed and Scopus. For the subject search, Medical Subject Headings were used. A total of 36 sources that mentioned the terms «cognitive function¼ and «functional transcranial Doppler¼ were selected for preliminary analysis. At the present stage, methodological problems are obvious, requiring the development and implementation of a standard package of targeted functional tests to assess cognitive status. Available equipment and software require technological solutions to ensure objective recording of changes in cerebral blood flow during testing and training.


Assuntos
Disfunção Cognitiva , Acidente Vascular Cerebral , Humanos , Cognição , Circulação Cerebrovascular , Disfunção Cognitiva/diagnóstico por imagem , Síndrome , Ultrassonografia Doppler Transcraniana/métodos
8.
Exp Physiol ; 109(4): 614-623, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38376110

RESUMO

The mean flow index-usually referred to as Mx-has been used for assessing dynamic cerebral autoregulation (dCA) for almost 30 years. However, concerns have arisen regarding methodological consistency, construct and criterion validity, and test-retest reliability. Methodological nuances, such as choice of input (cerebral perfusion pressure, invasive or non-invasive arterial pressure), pre-processing approach and artefact handling, significantly influence mean flow index values, and previous studies correlating mean flow index with other established dCA metrics are confounded by inherent methodological flaws like heteroscedasticity, while the mean flow index also fails to discriminate individuals with presumed intact versus impaired dCA (discriminatory validity), and its prognostic performance (predictive validity) across various conditions remains inconsistent. The test-retest reliability, both within and between days, is generally poor. At present, no single approach for data collection or pre-processing has proven superior for obtaining the mean flow index, and caution is advised in the further use of mean flow index-based measures for assessing dCA, as current evidence does not support their clinical application.


Assuntos
Pressão Arterial , Circulação Cerebrovascular , Humanos , Reprodutibilidade dos Testes , Homeostase/fisiologia , Circulação Cerebrovascular/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Ultrassonografia Doppler Transcraniana , Pressão Sanguínea/fisiologia
9.
Eur J Neurol ; 31(5): e16227, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38308448

RESUMO

BACKGROUND: The aim of this study was to analyze cold stimulation-induced changes in cerebral and cardiac hemodynamics. METHODS: Upon ingestion of an ice cube, the changes in resistance index, mean flow velocity and flow index of the middle cerebral arteries (MCA) were assessed using transcranial Doppler sonography. Extracranial duplex sonography was used to measure the mean flow velocity and resistance index of the right internal carotid artery (ICA). The change in mean arterial pressure, heart rate, root mean square of successive differences (RMSSD) and end-tidal carbon dioxide pressure were analyzed additionally. These changes were compared to sham stimulation. RESULTS: Compared with sham stimulation, cooling of the oral cavity resulted in significant changes in cerebral and cardiac hemodynamics. The cold stimulation decreased the resistance index in the MCA (-4.5% ± 5.4%, p < 0.0001) and right ICA (-6.3% ± 15.6%, p = 0.001). This was accompanied by an increase in mean flow velocity (4.1% ± 8.0%, p < 0.0001) and flow index (10.1% ± 43.6%, p = 0.008) in the MCA. The cardiac effects caused an increase in mean arterial pressure (1.8% ± 11.2%, p = 0.017) and RMSSD (55% ± 112%, p = 0.048), while simultaneously decreasing the heart rate (-4.3% ± 9.6%, p = 0.0001). CONCLUSION: Cooling of the oral cavity resulted in substantial changes in cerebral and cardiac hemodynamics resulting in a blood flow diversion to the brain.


Assuntos
Encéfalo , Hemodinâmica , Humanos , Velocidade do Fluxo Sanguíneo/fisiologia , Voluntários Saudáveis , Hemodinâmica/fisiologia , Encéfalo/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana , Boca , Circulação Cerebrovascular/fisiologia
11.
CNS Neurosci Ther ; 30(2): e14584, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38421125

RESUMO

AIMS: Most studies focus on dynamic cerebral autoregulation (dCA) in the middle cerebral artery (MCA), and few studies investigated neurovascular coupling (NVC) and dCA in the posterior cerebral artery (PCA). We investigated NVC and dCA of the PCA in healthy volunteers to identify sex differences. METHODS: Thirty men and 30 age-matched women completed dCA and NCV assessments. The cerebral blood flow velocity (CBFV) and mean arterial pressure were evaluated using transcranial Doppler ultrasound and a servo-controlled plethysmograph, respectively. The dCA parameters were analyzed using transfer function analysis. The NCV was evaluated by eyes-open and eyes-closed (24 s each) periodically based on voice prompts. The eyes-open visual stimulation comprised silent reading of Beijing-related tourist information. RESULTS: The PCA gain was lower than that of the MCA in all frequency ranges (all p < 0.05). Phase was consistent across the cerebrovascular territories. The cerebrovascular conductance index (CVCi) and mean CBFV (MV) of the PCA were significantly higher during the eyes-open than eyes-closed period (CVCi: 0.50 ± 0.12 vs. 0.38 ± 0.10; MV: 42.89 ± 8.49 vs. 32.98 ± 7.25, both p < 0.001). The PCA dCA and NVC were similar between the sexes. CONCLUSION: We assessed two major mechanisms that maintain cerebral hemodynamic stability in healthy men and women. The visual stimulation-evoked CBFV of the PCA was significantly increased compared to that during rest, confirming the activation of NVC. Men and women have similar functions in PCA dCA and NCV.


Assuntos
Acoplamento Neurovascular , Humanos , Masculino , Feminino , Acoplamento Neurovascular/fisiologia , Artéria Cerebral Posterior/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Homeostase/fisiologia , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/fisiologia , Ultrassonografia Doppler Transcraniana , Circulação Cerebrovascular/fisiologia , Pressão Sanguínea/fisiologia
12.
Ultrasound Med Biol ; 50(5): 751-759, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38418342

RESUMO

OBJECTIVE: Neurovascular coupling (NVC) represents the increase in regional blood flow associated with neural activity. The aim here was to describe a new approach to non-invasive measurement of NVC by spectral analysis of the cerebral blood flow velocity (CBFV) with transcranial Doppler. METHODS: In a sample of 20 healthy participants, we monitored systolic CBFV in the left posterior cerebral artery (PCA) during off (eyes closed) and on (flickering checkerboard) periods. The contralateral middle cerebral artery was simultaneously monitored as a control. Each participant was submitted to three experiments, each having five cycles, with increasing duration of the cycles, from 10 s (0.1 Hz) to 20 s (0.05 Hz) and lastly 40 s (0.025 Hz), half the time for on and for off periods, constituting a total of 6 min. The successive cycles were expected to cause oscillation in CBFV in a sinusoidal pattern that could be characterized by spectral analysis. We also measured the classic CBFV overshoot as the relative increase in percentage of systolic CBFV from baseline. The relationship and agreement between the two methods were analyzed by linear regression and Bland-Altman plots. In every participant, a clear peak of amplitude in the PCA CBFV spectrum was discernible at 0.1, 0.05 and 0.025 Hz of visual stimulation. RESULTS: On average, this amplitude was 7.1 ± 2.3%, 10.9 ± 3.5% and 17.3 ± 6.5%, respectively. This response contrasted significantly with an absent peak in middle cerebral artery monitoring (p < 0.0001). The spectral amplitude and classic overshoot were highly correlated and linearly related (p < 0.0001). CONCLUSION: NVC can be quantified by the spectral amplitude of PCA CBFV at slower and higher frequencies of visual stimulation. This method represents an alternative to classic overshoot without the need for stimulus marking or synchronization.


Assuntos
Acoplamento Neurovascular , Humanos , Acoplamento Neurovascular/fisiologia , Artéria Cerebral Média/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Ultrassonografia Doppler Transcraniana/métodos , Voluntários Saudáveis , Circulação Cerebrovascular/fisiologia
14.
BMC Neurol ; 24(1): 56, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321372

RESUMO

BACKGROUND: Parkinson's disease (PD) and vascular parkinsonism (VaP) have highly overlapping phenotypes, and different prognosis. This study comprehensively investigated the clinical, brain MRI and transcranial sonography differences between VaP and PD. METHODS: Forty-eight patients with PD, 27 patients with VaP, and 29 healthy controls were compared. All patients were assessed using the MDS-UPDRS, Berg Balance Scale (BBS), Ten-Meter Walking Test (10-MWT), Time Up and Go Test, and Non-Motor Symptoms Scale. Beck Depression Inventory, PD questionnaire- 39, international urine incontinence scale, cognitive assessment scales, MRI brain and transcranial colour-coded doppler. The study was registered on clinical-Trial.gov (NCT04308135) on 03/12/2020. RESULTS: VaP patients showed significantly older age of onset, shorter disease duration, lower drug doses and levodopa responsiveness, higher On and Off axial scores, On and Off BBS, higher On scores for PIGD, rigidity, bradykinesia and total motor MDS-UPDRS, lower On and Off tremor, lower-half predominance, lower asymmetrical presentation and symmetric index than PD patients. VaP patients had worse non-motor symptoms Scale (NMSS) than controls except for perceptual problems/hallucinations but better symptoms than PD patients except for urinary dysfunction. Quality of life (QoL) was impaired in VaP patients and was correlated with motor function and NMSs. The VaP group had significantly higher white matter lesions and brain atrophy, with lower hyperechogenicity of the substantia nigra and more impaired cerebral vascular resistance and vasoreactivity than the PD group. CONCLUSIONS: VaP has a characteristic motor and non-motor profile, with impaired QoL, white matter, and transcranial sonography abnormalities that differentiate it from PD. Further studies are warranted to explore the role of vascular lesions in the pathogenesis of VaP. TRIAL REGISTRATION: The registered identifier NCT04308135 on clinical-Trial.gov. Registered on 03/12/2020.


Assuntos
Doença de Parkinson , Humanos , Qualidade de Vida/psicologia , Estudos de Casos e Controles , Equilíbrio Postural , Estudos de Tempo e Movimento , Ultrassonografia Doppler Transcraniana
15.
Int J Mol Sci ; 25(3)2024 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-38338971

RESUMO

There is evidence to suggest that hormonal migraine is associated with altered cerebrovascular function. We aimed to investigate whether the expression of genes related to endothelial function in venous blood (1) might influence cerebrovascular function, (2) differs between hormonal migraineur and non-migraineur women, and (3) changes following resveratrol supplementation. This study utilised data obtained from 87 women (59 hormonal migraineurs and 28 controls) where RNA from venous blood was used to quantify gene expression and transcranial Doppler ultrasound was used to evaluate cerebrovascular function. Spearman's correlation analyses were performed between gene expression, cerebrovascular function, and migraine-related disability. We compared the expression of genes associated with endothelial function between migraineurs and non-migraineurs, and between resveratrol and placebo. The expression of several genes related to endothelial function was associated with alterations in cerebrovascular function. Notably, the expression of CALCA was associated with increased neurovascular coupling capacity (p = 0.013), and both CALCA (p = 0.035) and VEGF (p = 0.014) expression were associated with increased cerebral blood flow velocity in the overall study population. Additionally, VCAM1 expression correlated with decreased pulsatility index (a measure of cerebral arterial stiffness) (p = 0.009) and headache impact test-6 scores (p = 0.007) in the migraineurs. No significant differences in gene expression were observed between migraineurs and controls, or between placebo and resveratrol treatments in migraineurs. Thus, altering the expression of genes related to endothelial function may improve cerebrovascular function and decrease migraine-related disability.


Assuntos
Transtornos de Enxaqueca , Acoplamento Neurovascular , Humanos , Feminino , Resveratrol/farmacologia , Transtornos de Enxaqueca/genética , Ultrassonografia Doppler Transcraniana , Circulação Cerebrovascular/genética
16.
Microsc Res Tech ; 87(5): 948-956, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38174664

RESUMO

Agitated saline microbubbles (MBs) are a common contrast agent for determining right-to-left shunt (RLS) by the contrast transcranial Doppler (c-TCD). The size of the generated bubbles is not standardized in clinical practice. MBs were generated using the recommended manual method by reciprocating motion through two syringes. The bubble size distributions (BSD) were measured using the microscopic shadow imaging technique. The results show that the diameter of MBs is mainly distributed between 10 and 100 µm, the mean bubble size is between 21 and 34 µm, the Sauter mean diameter (D32) is primarily between 50 and 300 µm, and the standard deviation (SD) is between 6 and 17 µm in 80 experiments. It provides a more accurate basis for the recommended manual method instability. The high variance values of the BSD indicate that the manual method has low stability and repeatability. The results of this study can be useful for further improvement of the reliability of c-TCD in detecting RLS. RESEARCH HIGHLIGHTS: This study provided the first detailed descriptions of the MBs size distribution in a flowing contrast agent by the microscopic shadow imaging technique. It reveals significant differences in the bubble size of manual foaming during repeated manipulations for each individual and between individuals.


Assuntos
Meios de Contraste , Microbolhas , Humanos , Reprodutibilidade dos Testes , Ultrassonografia Doppler Transcraniana/métodos
17.
J Stroke Cerebrovasc Dis ; 33(3): 107575, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38232582

RESUMO

AIM: This study aimed to evaluate the feasibility of transcranial color-coded sonography (TCCS) and contrast-enhanced ultrasound (CEUS) in assessing middle cerebral artery (MCA) stem stenosis or occlusion compared to digital subtraction angiography (DSA). METHODS: A total of 48 cases including 96 MCAs suspected stem stenosis or obstruction in the MCA were assessed by TCCS, CE-TCCS, and DSA. The diameters of the most severe stenosis (Ds), proximal normal artery (Dn), and diameter stenosis rate of MCA were measured using both the color doppler flow imaging (CDFI) modality of TCCS or CEUS and the CEUS imaging modality. The intraclass correlation coefficients (ICCs) and 95 % confidence intervals (CI) were evaluated, and a weighted Kappa value was used to evaluate the intra-observer agreement, inter-observer agreement, agreement between CDFI modality and DSA stenosis or occlusion, and agreement between CEUS imaging modality and DSA stenosis or occlusion. RESULTS: The ICC results indicated excellent repeatability and reproducibility (all ICCs > 0.75; weighted Kappa values >0.81). Compared with DSA, the weighted Kappa values and 95 % CIs of stenosis (the first measurement was taken by two observers) of CDFI modality and CEUS imaging modality were 0.175 (0.041, 0.308) and 0.779 (0.570, 0.988) for observers A and 0.181 (0.046, 0.316) and 0.779 (0.570, 0.988) for observers B respectively. CONCLUSION: This study indicates that inter- and intra-observer agreements were good for the direct method of measuring percentages of MCA stenosis by TCCS and CEUS. CEUS imaging modality is a new and reliable imaging modality approach to evaluate the MCAs stenosis and occlusion.


Assuntos
Transtornos Cerebrovasculares , Artéria Cerebral Média , Humanos , Artéria Cerebral Média/diagnóstico por imagem , Constrição Patológica , Angiografia Digital/métodos , Reprodutibilidade dos Testes , Estudos de Viabilidade , Ultrassonografia Doppler Transcraniana/métodos , Sensibilidade e Especificidade
18.
J Ultrasound Med ; 43(5): 979-992, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38279568

RESUMO

Transcranial Doppler (TCD) is a repeatable, at-the-bedside, helpful tool for confirming cerebral circulatory arrest (CCA). Despite its variable accuracy, TCD is increasingly used during brain death determination, and it is considered among the optional ancillary tests in several countries. Among its limitations, the need for skilled operators with appropriate knowledge of typical CCA patterns and the lack of adequate acoustic bone windows for intracranial arteries assessment are critical. The purpose of this review is to describe how to evaluate cerebral circulatory arrest in the intensive care unit with TCD and transcranial duplex color-coded doppler (TCCD).


Assuntos
Morte Encefálica , Encéfalo , Adulto , Humanos , Morte Encefálica/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana , Ultrassonografia Doppler em Cores , Artérias , Circulação Cerebrovascular
19.
Neurocrit Care ; 40(1): 130-146, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37160846

RESUMO

BACKGROUND: Noninvasive neuromonitoring in critically ill children includes multiple modalities that all intend to improve our understanding of acute and ongoing brain injury. METHODS: In this article, we review basic methods and devices, applications in clinical care and research, and explore potential future directions for three noninvasive neuromonitoring modalities in the pediatric intensive care unit: automated pupillometry, near-infrared spectroscopy, and transcranial Doppler ultrasonography. RESULTS: All three technologies are noninvasive, portable, and easily repeatable to allow for serial measurements and trending of data over time. However, a paucity of high-quality data supporting the clinical utility of any of these technologies in critically ill children is currently a major limitation to their widespread application in the pediatric intensive care unit. CONCLUSIONS: Future prospective multicenter work addressing major knowledge gaps is necessary to advance the field of pediatric noninvasive neuromonitoring.


Assuntos
Lesões Encefálicas , Ultrassonografia Doppler Transcraniana , Humanos , Criança , Ultrassonografia Doppler Transcraniana/métodos , Espectroscopia de Luz Próxima ao Infravermelho , Estado Terminal , Unidades de Terapia Intensiva Pediátrica , Estudos Multicêntricos como Assunto
20.
J Ultrasound Med ; 43(2): 315-322, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37902179

RESUMO

PURPOSE: Aneurysmal subarachnoid hemorrhage (aSAH) is associated with high morbidity and mortality, which is largely attributable to secondary complications such as vasospasm and subsequent delayed cerebral ischemia. Transcranial Doppler (TCD) is recommended for the screening of vasospasm; however, technicians are not always available. We aimed to see how feasible and reliable bedside transcranial point-of-care ultrasound (POCUS) color-coded duplex sonography was compared with formal non-imaging TCD in measuring velocities and in diagnosing vasospasm. METHODS: This was a prospective observational study that took place in the neuroscience intensive care unit at a single academic medical center. Patients with aSAH who were undergoing formal TCDs were scanned on days 2-10 of their admission by physicians of ranging ultrasound experience. Absolute velocities were compared as well as the diagnosis of vasospasm via POCUS and formal TCDs. RESULTS: A total of 226 bedside ultrasound exams were performed and compared with 126 formal TCD studies. Sonographic windows were obtained in 89.4% of patients. Scans took 6.6 minutes to complete on average by the advanced group versus 14.5 minutes in the beginner. Correlation ranged from .52 in the beginner group to .65 in the advanced. When good quality of images obtained at a depth of 4-5 cm were reviewed, correlation of mean velocities increased to .96. Overall sensitivity for diagnosing vasospasm was 75%, with a specificity of 99% and negative predictive value of 99%. CONCLUSION: Overall, POCUS TCD cannot replace a formal study performed by expert sonographers. An abbreviated POCUS scan can be performed quickly, however, particularly with more experienced operators. POCUS TCD can also feasibly detect vasospasm, and accurate velocities can be obtained by those with all levels of ultrasound experience. Care must be taken on image interpretation that velocities are obtained at an appropriate depth to ensure appropriate insonation of the MCA as well as in optimal alignment with the vessel to obtain the most accurate velocities.


Assuntos
Médicos , Hemorragia Subaracnóidea , Vasoespasmo Intracraniano , Humanos , Estudos de Viabilidade , Reprodutibilidade dos Testes , Hemorragia Subaracnóidea/complicações , Hemorragia Subaracnóidea/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Vasoespasmo Intracraniano/diagnóstico por imagem , Vasoespasmo Intracraniano/etiologia , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...